National service telephone
86-514-86880701
Garhope measurement co.,LTD
86-514-86880701
Customer service: 86835585
Fax: 86-514-86889575
Website: www.garhope.com
Address: foreign capital industrial park in jiangdu district, yangzhou city, jiangsu province
Diaphragm pressure gauge used in the pipeline, there is no medium in the pipe, the pressure is not zero, in this case we have to clear the operation, clear the operation, we have to do the following to succeed. First of all, there is no medium in the pipeline. It does not mean that the pressure in the pipeline is zero. So the pressure transmitter to measure the actual pressure is in the pipeline (provided that the pressure transmitter installation has been calibrated) if the uncertainty can be cut out of the atmospheric pressure transmitter, pressure is almost zero, then the correct pressure transmitter measurement. Zero again with HART after clearing will change the pressure transmitter, if it is in the case of zero pressure gauges will certainly lead after the measurement is not accurate, such as measuring the landlord said value is 70kpa, the actual value may be larger, but not very accurate to 2.53kpa, the need to use other standard table to adjust know what is the difference.
1, before clearing the operation, you must first ensure the access diaphragm pressure gauge is zero
2, for the low range, micro range meter, the meter will almost always dismounting into the position error of film, so the process pressure to zero, or open the valve, or disconnect the pressure tube, and zero after clearing operation
3, support for the use of hand to clear the meter, may be more?
Some table count, with clear button, some are single button cleared, and some are double bond cleared
I left the picture on the section table, using the SET key and long key, press the reset, and long bond, for direct measurement display
4, there are some intelligent meter, self diagnosis will be more complete design,
My head on that table, when the meter placement is absolute pressure sensor, even press the reset button, the system will automatically execute the function of shielding, shielding 5 clear function is good, but also some engineers, is required by the absolute pressure meter, observation table pressure, positive pressure or negative pressure is observed, general situation so, they will feel inconvenient, the design of meter when we are also planning a menu and a channel parameter calculation
When touching the menu input pressure value, display the channel value, is due to the environmental pressure, atmospheric pressure, average a year change amount, about 3KPa, a month of fluctuation is usually less than 0.3kPa, therefore it is not necessary to change the atmospheric pressure drops frequently set value